Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home Use

Product Details
Classification: Ivd
Type: Ivd
Certification: CE
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 7 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home Use
  • Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home Use
  • Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home Use
  • Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home Use
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Features&Benefits
  • Main Products
  • Company Profile
Overview

Basic Info.

Model NO.
IL-6
Group
All Patients with Inflammation
Certificate
CE
Material
Plastic
Application
Disease Test
Specimens
Blood Sampling
Quality Guarantee Period
2 Years
Feature 1
Fast Results in 10 Minutes
Feature 2
High Sensitivity and Specificity
Feature 3
Factory Price
Transport Package
Box/Carton
Specification
10 tests/box, 20 tests/box, 25 tests/box, 30 tests
Trademark
Singclean
Origin
China
HS Code
3002150050
Production Capacity
100000/Week

Product Description

Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to help detect inflammation

Product Description

Introduction

Interleukin-6 is mainly produced by Th2 cells and secreted by T lymphocytes, B lymphocytes, fibroblasts, endothelial cells, keratinocytes, hepatocytes and bone marrow cells. Its relative molecular weight is 26kDa. It is a glycoprotein composed of 212 amino acid residues. Interleukin-6 is the first biomarker to appear after inflammatory reaction. In different inflammatory diseases, the content of interleukin-6 is significantly different. The increased level of interleukin-6 caused by bacterial infection is significantly higher than that caused by non-bacterial infection, and the level of interleukin-6 is directly proportional to the severity of inflammation and infection. Interleukin-6 is also a sensitive early warning index of sepsis, and has a good correlation with the severity and prognosis of sepsis. As an inflammatory factor, the level of interleukin-6 is also closely related to cardiovascular and cerebrovascular diseases such as atherosclerosis and acute myocardial infarction (AMI).

Indications for Use
The kit is used for quantitative determination of interleukin-6 (IL-6) in human serum, plasma or whole blood samples in vitro.

Who Should Have the Interleukin-6 (IL-6) Test?
Patients suffering from inflammatory conditions;Patients with diabetes, stroke or with cardiovascular disease and C-19-infected patients. Interleukin-6 (IL-6) may be used to help evaluate a person who has a condition associated with inflammation, such as lupus or rheumatoid arthritis, or with infection, such as sepsis. It may also be used in the evaluation of diabetes, stroke, or cardiovascular disease.
Besides, Interleukin-6 (IL-6) Test Kit can help determine the risk of developing severe coagulation-related consequences such as disseminated intravascular coagulation (DIC) and acute respiratory distress syndrome (ARDS) in severe cases of C-19 infection.
Combined with the highly specific PCT joint inspection, it can early warning of sepsis, reflect the severity of infection, evaluate the treatment effect, and help the clinic to quickly judge the patient's situation

Detailed Photos

Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home Use
Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home Use

Features&Benefits

Accurate: the fluorescence immunochromatography method based test kit has higher accuracy.
Easier to read: based on fluorescence immunochromatography, easier to read test result than colloidal gold immunochromatography.
Easy for storage: it can be stored at room temperature (4ºC~30ºC).
Longer validity period: 18 months of validity period.


 

Product Performance Index
a) Accuracy:When tested with standard IL-6, the relative deviation (B%) between the detection mean value and the target value shall be within ± 15%.
b) Linear range: The linear range is 7pg / ml ~ 5000pg / ml, and the linear correlation coefficient r0.9900.
c) Blank limit: not higher than 7ng/mL;
d) Precision:
In-batch precision: The coefficient of variation (CV) is not more than 15%;
Precision between batches: The relative range between batches is not more than 15%.


Product Information
Product Name Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography)
Method Fluorescence immunochromatography
Specimen Whole blood, Plasma, Serum
Specification 10 tests/box, 20 tests/box, 25 tests/box, 30 tests/box, 50 tests/box, 100 tests/box.
Components Each pouch contains a test card and a desiccant; the test card is composed of a shell and a test strip, the test strip is composed of sample pad, fluorescent pad (fixed with fluorescent labeled IL-6 monoclonal antibody 1), nitrocellulose membrane (coated with IL-6 monoclonal antibody 2 and goat anti-mouse IgG), filter paper and PVC plastic plate
Test time 15 mins
[Applicable instrument]
Fluorescence immunoassay analyzer
It should be purchased separately and can be used for different Test Items, like CK-MB, IL6, PCT.
For different tests, scan the QR code accordingly.



Test Procedure
Please read the instructions of the test kit and the manual of the fluorescence immunoanalyzer carefully before use.
a) Bring the test kit and sample to be tested to room temperature.
b) Make sure the ID card matches the batch number of the kit, and insert the ID card into the card reading area of the instrument to read the information.
c) Open the inner package of the test card, take out the test card; draw 75μL of serum plasma sample, drop vertically to the test card sampling place, and start timing; draw 75μL whole blood, vertically drop it to the test card sampling place, and immediately add 1 drop whole blood diluent at the sampling place and start timing.
d) After adding the sample, click "Start Test" on the screen of the fluorescence immunoanalyzer, and the test card will react at room temperature for 15 minutes; insert the test card into the test card slot of the fluorescence immunoanalyzer, and the instrument will automatically test the test card; The test results can be seen on the display screen of the immunoassay analyzer. Click "Print" on the screen to print the results.


Positive Judgment Value or Reference Interval
Normal reference value:<7pg/mL.
Due to differences in geography, race, gender and age, it is recommended that each laboratory establish its own positive judgment value or reference interval.
 

Test result

(For reference only, not used as clinical diagnostic criteria, test results need to be combined with other clinical and laboratory data for clinical diagnosis)

Content of IL-6(pg/mL) Clinical application suggestions
<7 Normal value
7-150 Indicates mild inflammation or mild infection.
150-250 Suggests general bacterial infection or systemic inflammatory reaction.
>250 Suggests may be sepsis.


Limitations
a) This test kit is only for the test of human serum, plasma or whole blood samples. Abnormal hematocrit samples have an impact on the results of the whole blood test. The test results of serum, plasma and whole blood are not significant difference when the hematocrit is between 21% and 48%.
b) The test results need to be combined with other clinical and laboratory data, and if the IL-6 test results do not match the clinical assessment, further testing is required.
c) False positive results can be caused by: cross-reaction of antibody-like components in the blood; some non-specific components in blood have similar antigenic determinants to capture fluorescent-labeled antibodies, such as anisotropic antibodies and rheumatoid factors. In view of the above reasons, the test results should be combined with the patient's medical history and other laboratory results performed.
d) Hemoglobin, triglycerides and bilirubin in the blood sample can interfere with the test results, where the maximum allowable concentrations are 5g/L, 10g/L and 0.2g/L, respectively.
e) False positive results can be caused by: some unknown components shield the antigenic determinants from binding to the antibody; the unstable IL-6 antigen gradually degrades with time and temperature and cannot be recognized by the antibody. Valid test results depend on a good reagent and sample storage environment.
f) Other factors, including technical reasons, operational errors and other sample factors, may also cause errors in test results.

Certificate
CE      ISO13485

 

Main Products

Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home Use

Company Profile

Singclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home UseSingclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home UseSingclean Interleukin-6 (IL-6) Test Kit (Fluorescence Immunochromatography) to Detect Inflammation Home Use

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier