• Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis
  • Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis
  • Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis
  • Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis
  • Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis
  • Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis

Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis

Material: Plastic
Test Sample: Whole Blood/Serum
Certification: CE/ ISO9001/ ISO13485
Shelf Life: 1 Year
Instrument Classification: Class III
Accuracy: 99.8%
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Zhejiang, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 6 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Overview
  • Product Description
  • Detailed Photos
  • Main Products
  • Company Profile
Overview

Basic Info.

Transport Package
48pieces/96pieces
Specification
20ng/ml
Trademark
Singclean
Origin
China
Production Capacity
100000 Piece/Pieces Per Month

Product Description

Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis

Product Description

Introduction

AFP is a glycoprotein with a mol wt of ~65-70 kDa. It has approx. 4% carbohydrates. During fetal development, Alpha-Fetoprotein(AFP) is secreted at high levels and then drops to very low levels in adult life. AFP reappears in serum at high levels in malignant diseases of hepatocellular, testicular, nonseminomatosus origin, and occasionally other entodermal origin. AFP may be slightly elevated or persisted in patients with large hepatic metastases or viral hepatitis. AFP measurement is widely accepted as tumor marker and for monitoring the therapeutic effectiveness of hepatocellular and other cancer.

AFP concentration is also high in the amniotic fluid during early stages of pregnancy. AFP levels decline in the later part of the pregnancy. Elevated amniotic AFP levels are indicative of open neural tube defects (spina bifida or anencephaly) and in several fetal hemolytic diseases, omphlocele, esophageal artresia, congenital nephrosis, intrauterine death or fetal bleeding into the amniotic fluid. For diagnostic purpose, ultrasonography and acetylcholine esterase measurement should be performed in conjunction with AFP.

AFP ELISA Test is designed for the quantitative determination of AFP in serum specimens to aid the diagnosis of Primary Hepatocellular Carcinoma or fetal open neural tube defects.

Application 
The Alpha fetoprotein (AFP) assay kit is intended for quantitative determination of the Alpha fetoprotein (AFP) concentration in human serum

Specificity 
The specificity of AFP ELISA kit is determined by measuring interference from high concentrations of human albumin and human Vitamin D binding protein. No interference is detected.
 

Detailed Photos

Singclean CE Marked Afp Rapid Diagnostic Test for Viral HepatitisSingclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis


Assay Procedure Summary
Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis

Product Specification
Contents         Pack size 48 tests /box 96 tests /box
Micro well plate 1 X 48-well plate 1 X 96-well plate
AFP standard ( 0ng/mL) 1 X 0.3mL/vial 1 X 0.5mL/vial
AFP standard (5ng/mL) 1 X 0.3mL/vial 1 X 0.5mL/vial
AFP standard (20ng/mL) 1 X 0.3mL/vial 1 X 0.5mL/vial
AFP standard (50ng/mL) 1 X 0.3mL/vial 1 X 0.5mL/vial
AFP standard (200ng/mL) 1 X 0.3mL/vial 1 X 0.5mL/vial
AFP standard (500ng/mL) 1 X 0.3mL/vial 1 X 0.5mL/vial
anti-AFP-HRP conjugate 1 X 6mL/bottle 1 X 12mL/bottle
AFP diluent 1 X 6mL/bottle 1 X 12mL/ bottle
Wash buffer(20X) 1 X 10mL/bottle 1 X 20mL/ bottle
TMB substrate solution 1 X 6mL/bottle 1 X 12mL/ bottle
Stop solution 1 X 3mL/bottle 1 X 6mL/ bottle
Closure plate membrane 2pcs 2pcs
Instruction for use 1pcs 1pcs

Storage and Expiry date
1.Store the kit at 2°C ~ 8°C. Do not freeze.
2.It expires after 12 months in the storage conditions.
3.The kit must be used within 3 months after the reagents were openedFAQ

Our Service
1.Factory direct price .price is competitive with high quality.
2.Original manufacturer provide OEM service for you.  OEM Service including private labeling, color box and pouch printing, customized assembly are available.
3.Smooth delivery near Shanghai and Ningbo Port.
4.Limited free samples are available sent for your evaluation.

Payment & Package& Delivery
* Payment:West Union, PayPal, T/T
* Package: 48 Sets/plate,96 Sets/plate
* Delivery method: UPS, TNT, FedEx, DHL, EMS and etc.

Main Products

Singclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis

Company Profile

Singclean CE Marked Afp Rapid Diagnostic Test for Viral HepatitisSingclean CE Marked Afp Rapid Diagnostic Test for Viral HepatitisSingclean CE Marked Afp Rapid Diagnostic Test for Viral Hepatitis

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now