Gold Member Since 2016
Audited Supplier
Hangzhou Singclean Medical Products Co., Ltd.

Home Urine Test, Diagnostic Test, Rapid Test Kit manufacturer / supplier in China, offering One Step Ngal Acute Kidney Injury Aki Rapid Test Kit (Urine), Ce Approved Rapid Test Kit Lh Ovulation Test Midstream, Urine One Step Diagnostic Drug of Abuse Rapid Test Kit and so on.

(/ )

Supplier Homepage Product IVD products One Step Ngal Acute Kidney Injury Aki Rapid Test Kit (Urine)

One Step Ngal Acute Kidney Injury Aki Rapid Test Kit (Urine)

FOB Price: US $1-2.5 / Piece
Min. Order: 500 Pieces
Min. Order FOB Price
500 Pieces US $1-2.5/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 10000/Day
Payment Terms: L/C, T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Type: Test Strips & Test Tube
  • Certification: CE, ISO13485
  • Quality Guarantee Period: Two Years
  • Logo Printing: Singclean or Customized Brand
  • Trademark: Singclean or Customized brand
  • Specification: 1pc/box; 25 pcs/box; 50 pcs/box; 100 pcs/box
  • HS Code: 38220010
  • Material: Colloidal Gold
  • Ethylene Oxide Sterilization: Without Ethylene Oxide Sterilization
  • Group: Adult
  • Medical Device Regulatory Type: Type 2
  • Transport Package: Carton or Customized Package
  • Origin: China
Product Description

INTENDED USE

One Step Test for NGAL (Colloidal Gold) applies colloidal gold Immunol Chromatography, for the qualitative detection of Neutrophils Gelatinase Associated Lipocalin (NGAL) in human urine specimen. This test is used as an aid in the early diagnosis of acute kidney injury, risk classification and treatment monitoring.

PERFORMANCE CHARACTERISTICS/FEATURES

  • Specimen: Urine.
  • Accuracy: > 99 %.
  • High Sensitivity: 20 ng/ml
  • Certification: Declaration of conformity according to the directive 98/79/EC.
  • Format: Strip, cassette, midstream
  • Wide linear range:5-300ng/ml
  • Small sample size: 3 drops of urine

SPECIFICATION 

Specification
Cat.#Assay TypeSensitivitySpecimenQty/KitShelf Life
KD-N21Quantitative 20ng/mLUrine50T24 months

MATERIALS PROVIDED

  • One Step NGAL Rapid Test Kit, individually packed.
  • Package insert.
  • Disposable pipette.One Step Ngal Acute Kidney Injury Aki Rapid Test Kit (Urine)

       One Step Ngal Acute Kidney Injury Aki Rapid Test Kit (Urine)


MATERIALS REQUIRED BUT NOT PROVIDED

  • Specimen collection container.
  • Timer.


SPECIMEN COLLECTION

  • One Step NGAL Rapid Test Kit is intended only for use with human urine specimens.
  • Though urine specimens from any time of day can be used, first morning urine specimens are preferred, as they contain the highest concentration of Neutrophils Gelatinase Associated Lipocalin.
  • Urine specimens must be collected in clean, dry containers. Ensure that the volume of specimen collected is sufficient to submerge the dip region of the device.
  • Perform testing immediately after specimen collection. Do not leave specimens at room temperature for prolonged periods. Specimens may be stored at 2-8 °C for up to 48 hours. For long term storage, specimens should be frozen at -20 °C.
  • Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing.
  • Avoid repeated freezing and thawing of specimens.
  • If specimens are to be shipped, pack them in compliance with all applicable regulations for transportation of etiological agents.

PROCEDURE

  1. Bring tests, specimens to room temperature (15-30 °C) before use.
  2. Remove the test from its sealed pouch and use it as soon as possible. For best results, the assay should be performed within one hour.
  3. Place the test device on a clean and level surface.
  4. Using the provided disposable pipette, transfer 3 drops of specimen (approximately 120 μl) to the specimen well (S) of the device and start the timer.
  5. Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.
  6. Read the result at 5 minutes.

 

STORAGE

Original packaging should be stored in the 4-30 ºC, a cool, dark, dry place,  frozen is avoid.

The period of validity: 24 months .

OUR SERVICES

8-24 hours online services

OEM,ODM and Customized is available

Quickly delivery time

Quickly and professional service after sales

    ABOUT US
    One Step Ngal Acute Kidney Injury Aki Rapid Test Kit (Urine)
    One Step Ngal Acute Kidney Injury Aki Rapid Test Kit (Urine)



    One Step Ngal Acute Kidney Injury Aki Rapid Test Kit (Urine)




     
    You Might Also Like
    Send your message to this supplier
    Avatar
    Ms. Lizzy
    IVD sales manager
    *From:
    To: Ms. Lizzy
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now

    Find Similar Products By Category